Glossary entry (derived from question below)
German term or phrase:
erweiterte Grundausbau
English translation:
extended basic fit-out
Added to glossary by
jackiekiefer
Nov 2, 2021 15:31
2 yrs ago
23 viewers *
German term
erweiterte Grundausbau
German to English
Tech/Engineering
Architecture
Die Liegenschaft ist totalsaniert und wird im erweiterten Grundausbau oder auf Wunsch auch im individualisierten Vollausbau vermietet.
Description of a new office building in Switzerland.
I'm puzzled as to what exactly is meant by "erweiterten Grundausbau" here. Any suggestions appreciated. Thanks.
Description of a new office building in Switzerland.
I'm puzzled as to what exactly is meant by "erweiterten Grundausbau" here. Any suggestions appreciated. Thanks.
Proposed translations
(English)
5 | Cat. Fit-Out | Johannes Gleim |
3 +1 | extended basic interior construction | Barbara Schmidt, M.A. (X) |
4 | extended basic modular structure | Cillie Swart |
3 | extended base/basic construction (design) | David Hollywood |
Proposed translations
21 hrs
Selected
Cat. Fit-Out
Innenausbau | completion of the interior, internal finish(ing), interiorwork, inner [inside] fixtures
Innenausbau/fertiger | inner fixtures
Grundausstattung /technisch | basic equipment, smale-scale equipment
(Gelbrich, Fachwörterbuch Architektur und Bauwesen)
Canzler was responsible for the planning and project supervision of the technical equipment for the basic fit-out.
canzler.de
Canzler war für die Planung und Objektüberwachung der Technischen Ausrüstung für den Grundausbau verantwortlich.
canzler.de
https://www.linguee.com/english-german/translation/basic fit...
Fit out refers to the process of making an internal space suitable for occupation. It’s the transformation of a concrete shell into a working space; from installing facilities (like the loo!) and raising the flooring, to creating internal spaces, such as meeting rooms, breakout spaces and kitchens.
As the tenant, it’s important that you confirm with your landlord or developer what level of finish they’ll provide. Often a space will be provided by the landlord or developer as either a Shell and Core or a Cat A fit out, leaving it up to the tenants to create the final 'working' space through what we call as a Cat B fit out.
https://www.overbury.com/knowledge/insights/fit-out-q-a-diff...
Cat A Fit Outs
Refurbishments encompassing the basic structure of a renovation, without furnishings, is referred to as Category A. These spaces are generally habitable, yet empty spaces landlords utilise as basic structures to build upon.
:
Cat B Fit Outs
Category B builds upon the Cat A option by adding furnishing, fixtures and other finishing elements. No need to wait to move in, and in fact our competent and skilled project managers will be able to support your business in the transition.
https://imperialbuild.co.uk/cat-a-cat-b-fit-out/
he scale of the office fit-out you’ll have to undertake will also depend on whether you’ve purchased your office space or are leasing it, as most building owners will ensure at least a basic fit-outhas been completed before letting out an office.
https://blog.realla.co.uk/a-guide-to-your-office-fit-out-and...
Category A Fit Out refers to the tenant’s own space Fit Out. This is the basic Fit Out and includes all the processes like electrical and mechanical installations. Suspended Ceilings, Fire Systems, Lighting, Air Conditioning, are included in this Fit Out. In Category A Fit Out, you can expect grid ceilings, fitted lights, raised floors, internal surface finishes, blinds, etc.
Category B is developing the internal space according to the tenant’s requirements. Category A is a blank canvas and Category B is filling out that canvas. With Category B, you can have the chance to create a new vision that perfectly matches your company. This makes the office functional that includes Private office spaces, IT Common Rooms, Kitchen/ Snack areas, Reception Area, Floor finish, Doors, Meeting and Conference Rooms, Installation of Furniture and so on.
https://www.proz.com/kudoz/7014280
Innenausbau/fertiger | inner fixtures
Grundausstattung /technisch | basic equipment, smale-scale equipment
(Gelbrich, Fachwörterbuch Architektur und Bauwesen)
Canzler was responsible for the planning and project supervision of the technical equipment for the basic fit-out.
canzler.de
Canzler war für die Planung und Objektüberwachung der Technischen Ausrüstung für den Grundausbau verantwortlich.
canzler.de
https://www.linguee.com/english-german/translation/basic fit...
Fit out refers to the process of making an internal space suitable for occupation. It’s the transformation of a concrete shell into a working space; from installing facilities (like the loo!) and raising the flooring, to creating internal spaces, such as meeting rooms, breakout spaces and kitchens.
As the tenant, it’s important that you confirm with your landlord or developer what level of finish they’ll provide. Often a space will be provided by the landlord or developer as either a Shell and Core or a Cat A fit out, leaving it up to the tenants to create the final 'working' space through what we call as a Cat B fit out.
https://www.overbury.com/knowledge/insights/fit-out-q-a-diff...
Cat A Fit Outs
Refurbishments encompassing the basic structure of a renovation, without furnishings, is referred to as Category A. These spaces are generally habitable, yet empty spaces landlords utilise as basic structures to build upon.
:
Cat B Fit Outs
Category B builds upon the Cat A option by adding furnishing, fixtures and other finishing elements. No need to wait to move in, and in fact our competent and skilled project managers will be able to support your business in the transition.
https://imperialbuild.co.uk/cat-a-cat-b-fit-out/
he scale of the office fit-out you’ll have to undertake will also depend on whether you’ve purchased your office space or are leasing it, as most building owners will ensure at least a basic fit-outhas been completed before letting out an office.
https://blog.realla.co.uk/a-guide-to-your-office-fit-out-and...
Category A Fit Out refers to the tenant’s own space Fit Out. This is the basic Fit Out and includes all the processes like electrical and mechanical installations. Suspended Ceilings, Fire Systems, Lighting, Air Conditioning, are included in this Fit Out. In Category A Fit Out, you can expect grid ceilings, fitted lights, raised floors, internal surface finishes, blinds, etc.
Category B is developing the internal space according to the tenant’s requirements. Category A is a blank canvas and Category B is filling out that canvas. With Category B, you can have the chance to create a new vision that perfectly matches your company. This makes the office functional that includes Private office spaces, IT Common Rooms, Kitchen/ Snack areas, Reception Area, Floor finish, Doors, Meeting and Conference Rooms, Installation of Furniture and so on.
https://www.proz.com/kudoz/7014280
4 KudoZ points awarded for this answer.
Comment: "In the end I went for "extended basic fit-out" since UK English was specified and "fit-out" seems to be the best translation for "Ausbau" in this context. Thanks to everyone for their input!"
+1
12 mins
extended basic interior construction
Unter dem Grundausbau versteht man primär Kosten, die mit dem erstellen der Liegenschaft anfallen. Der Grundausbau einer Gewerbeliegenschaft umfasst die fertig gebaute Liegenschaft, ausgenommen ist die Mietfläche (HNF), die im Rohbau (nach Abschluss Baumeisterarbeiten) erstellt ist.
https://www.pom.ch/de/produkte/fm-monitor/fm-monitor-wiki/ko...
siehe auch
https://www.youtube.com/watch?v=T3JD4efRxrk
https://www.pom.ch/de/produkte/fm-monitor/fm-monitor-wiki/ko...
siehe auch
https://www.youtube.com/watch?v=T3JD4efRxrk
3 hrs
extended basic modular structure
The property has been completely renovated and is rented out in an extended basic version or, on request, in an individualised full version.
11 hrs
extended base/basic construction (design)
my ideas
Discussion
http://www.proz.com/kudoz/german-to-english/real-estate/2857...